Colorado Springs runs on heat from September through May. When the reversing valve or defrost cycle fails, it fails on the system doing most of the year's work.
A mini split that blows cold air in a Colorado Springs winter is not something to live with while you wait and see. Below freezing outside, a unit stuck in defrost or not switching over from cooling can leave a room cold fast, and El Paso County winters do not give you much room to guess at the cause. It could be the reversing valve, a control board issue, or a problem with the outdoor unit icing over and not clearing. Figuring out which one takes someone who works on these systems and knows what to check first. Send your information through and you get matched with a contractor who handles mini splits in this area, and they will reach out to you directly. No more searching through listings or calling around to find someone who knows this equipment. That part is done once you submit the form.
A mini split that won't heat usually comes down to one of a few things. The unit may still be set to cool, or stuck in a defrost cycle it isn't finishing. It could also be a refrigerant leak, a failing reversing valve, or ice built up on the outdoor coil that's blocking airflow. In Colorado Springs, outdoor temperatures below freezing make this worse. A heat pump works by pulling heat from the outside air, and the colder it gets, the harder that unit has to work, so a system that's already low on refrigerant or has a weak reversing valve often shows the problem for the first time once winter sets in. If the outdoor unit is coated in frost or ice that isn't melting during its normal defrost cycle, that's a sign something mechanical needs attention, not just cold weather. Left alone, a mini split that can't heat properly will keep running without warming the room, and in freezing temperatures that's not something to wait out.
Cooling runs July through August
Two months of cooling is a short stretch, so a mini split that won't heat is the problem you'll actually face most of the year.
Heat runs September through May
Nine months of heat means your mini split's heating side carries the real load here, and a reversing valve or defrost fault shows up fast.
Power here costs 15.63 cents per kilowatt-hour
At 15.63 cents per kilowatt-hour, a unit that won't switch out of defrost or keeps icing over runs the compressor for heat you never get.
NOAA nClimDiv 1991-2020 · EIA-861 2025
A mini split doesn't burn anything to make heat. It pulls warmth out of the outside air, even cold air, and moves it inside through refrigerant. The reversing valve is what decides which direction that refrigerant flows. Switch the thermostat to heat and the valve is supposed to flip, sending warm refrigerant to the indoor head instead of cold. If the valve sticks in the cooling position, the indoor head blows cold air no matter what the thermostat is set to.
Cold outside air also means ice on the outdoor coil. That's normal in an El Paso County winter, and the system is built to handle it through a defrost cycle that runs automatically, melting the ice before switching back to heating. The outdoor fan has to keep turning through that whole cycle to clear the coil. If the fan motor is weak or failing, the coil can stay iced over, and defrost either runs long or never completes. Either way, the indoor head keeps pushing air that never got warmed.
Refrigerant charge matters just as much. A unit that's lost refrigerant to a slow leak can't pull enough heat out of cold air to send inside, even with the valve working and the coil clear. Many units will flag a fault code when something in this chain fails, and that code is often the fastest way for a technician to know whether to check the valve, the defrost sensor, the fan motor, or the charge first.




A mini split blowing cold air when it's 20 degrees outside isn't a wait and see problem. Nine months of the year this unit is what keeps your house warm, so when the heating side stops working you feel it the same day, not after a few weeks of it running poorly. A stuck reversing valve or a defrost cycle that won't release doesn't get better on its own, and the longer ice sits on that outdoor coil the harder the system has to work once it does switch over. Someone who repairs mini splits for a living can tell you in a visit whether this is the valve, the refrigerant charge, or the defrost control, and get it sorted before the cold does more to your place than it already has. Send the request and let a local contractor take it from here.
Calling right away makes sense when the outdoor unit is iced over past what one defrost cycle clears, when the indoor head is blowing air that's cold rather than just cool, or when the temperature outside is already below freezing and dropping. None of those get better by giving it another day. A mini split in that state is losing the fight against a Colorado Springs night, and the room it heats will keep sliding until someone opens up the unit and finds the reversing valve, the refrigerant level, or whatever else has quit doing its job. Waiting doesn't give the unit a chance to sort itself out. It gives the cold air more time to win.
Some signs are worth watching before you pick up the phone. A room that's running a couple degrees cooler than the thermostat setting, a unit that's slower to catch up after a cold snap, or frost on the outdoor coil that clears on its own within an hour are all things a mini split can work through without help. The system is built to handle short dips in performance during a hard winter. What tells you it's past that point is the gap getting wider instead of narrower, or the unit running nonstop without the room ever reaching temperature. At that point watching has told you what you needed to know, and it's time to get someone out to look at it.


Colorado Springs runs on heat from September through May. When the reversing valve or defrost cycle fails, it fails on the system doing most of the year's work.
Below this, outdoor coils ice over fast. A working defrost cycle melts that ice in minutes; a failing one leaves the coil buried and the unit blowing cold.

A mini split that won't heat is doing one of a few specific things wrong: stuck in cooling mode, caught in a defrost cycle that won't finish, low on refrigerant, or working against a reversing valve that's failed. None of those fix themselves by running the system longer or turning it off and on again. Someone has to look at the outdoor coil, check the charge, and see what the reversing valve is actually doing.
You don't have to figure out which one it is before you call. Send the request and a contractor who works on mini splits in El Paso County takes it from there, matched to what you've described about your system. That's the part that's off your plate once the form goes in. You're not left tracking down who's available or explaining the problem twice. You just wait to hear back.



Get the right pro for your mini split
Send the request and finding a pro stops being your problem.